• Users Online: 93
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 2  |  Issue : 2  |  Page : 68-72

Safety of continuing warfarin therapy in patients undergoing cardiac resynchronization therapy device implantation


1 Department of Cardiology, Regions Hospital, St. Paul, Minnesota; Health Partners Medical Group, Minneapolis, USA
2 University of Minnesota Medical School, Minneapolis, Minnesota, USA
3 Department of Cardiology, Regions Hospital, St. Paul, Minnesota; Health Partners Medical Group, Minneapolis; University of Minnesota Medical School, Minneapolis, Minnesota, USA

Correspondence Address:
Dr. Dennis W.X. Zhu
Mail Stop 11102M, 640 Jackson Street, St. Paul, MN 55101
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/IJHR.IJHR_5_17

Rights and Permissions

Background: Continuing warfarin therapy is considered safe for patient undergoing pacemaker or implantable cardioverter defibrillator procedures, but less evidence exists for patients undergoing cardiac resynchronization therapy (CRT) device implantation. Subjects and Methods: We retrospectively evaluated 136 consecutive patients who received a CRT device. Three periprocedural anticoagulation strategies were utilized: Group 1, continuation of therapeutic warfarin; Group 2, cessation of warfarin with heparin bridging; and Group 3, cessation of anticoagulation temporarily. Groups were compared on the incidence of complications. Results: Of the 136 patients, 87 (64%) were in Group 1, 18 (13%) were in Group 2, and 31 (23%) were in Group 3. Group 1 patients had an international normalized ratio of 2.3 ± 0.5, which was significantly higher than the other two groups. Coronary sinus dissection occurred in four patients: Three in Group 1 and one in Group 2, but no patient experienced pericardial effusion or tamponade. Group 2 experienced a higher incidence of pocket hematoma (P = 0.0065) and a longer length of hospital stay (P = 0.0069) than Group 1. Transient ischemic attack occurred in one patient in Group 3. Conclusion: Continuing warfarin with therapeutic international normalized ratio seems to be safe in individuals undergoing CRT device implantation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4987    
    Printed450    
    Emailed0    
    PDF Downloaded378    
    Comments [Add]    
    Cited by others 1    

Recommend this journal